2021年最新无码国产在线视频_欧美日韩在线免费观看_96在线看片免费视频国产_日本强伦姧人妻69影院_午夜福利视频无码一二三_日韩女主播福利视频_欧美亚洲麻豆二区_成人激情影院在线观看_女邻居的大乳中文字幕_2020年最新国产精品正在播放

Hotline: +86-021-57278880
Language:   
Your current location: ProductsOther ValvesCorrugated Flame Arrester

RZGB-1 Corrugated Flame Arrester

Product overview

Product model: RZGB-1
Nominal diameter: DN50~300mm (2"~12")
Nominal pressure: PN0.6~5.0MPa
Operating temperature: ≤480℃
Main material: carbon steel WCB, stainless steel 304, 316
Applicable medium: class A, oil, hydrogen and oxygen liquefaction, kerosene, diesel oil, toluene, crude oil, etc
Connection type: flange connection (II) internal thread connection (III) external thread connection (IV)
Design standard: GB5908-86, GB1347-92
Flange standard: HG 20592-97, ANSI B 1.6, GB HGJ SH JB

RZGB-1 Corrugated Flame Arrester product details

RZGB-1 Corrugated Flame Arrester Overview:
RZGB-1 Corrugated Flame Arrester produced and sold by Baigang valve group is widely used in oil storage tanks, is to prevent accidental fire invade the tank, to prevent accidents, is the ideal product for tank fire. 

RZGB-1 Corrugated Flame Arresterperformance and features:

• The flame arrester has the advantages of reasonable structure, light weight, corrosion resistance and explosion-proof performance, and can withstand fire for 13 times in a row with a subsonic flame test. 
Flame arrester easy to repair, easy to install, do not check when removing the breathing valve. Resistance to burning qualified, resistant to burning test 1 hour without tempering. 
• The flame arrester core is stainless steel, corrosion-resistant and easy to clean. Shell hydraulic test qualified.


RZGB-1 Corrugated Flame Arrester Scope:
The flame arrester is suitable for pipes, flash point of less than 28 ℃ Class A, oil, hydrogenated liquefied and flash point of less than 60 ℃ of kerosene, diesel, a stupid, crude oil And so on, can be used with the respiratory valve supporting the use, but also can be used alone, within the floating roof tank vent, gas tank on the ground floor gas tank. 
 
RZGB-1 Corrugated Flame Arresterrepair and maintenance:
In order to ensure the performance of flame arrester to achieve the purpose of safe use, flame arresters should be regularly checked and maintained. 
 • Flame arresters are inspected semi-annually to check if the fire barrier core is clogged, deformed, etched. 
 • It is found that the plugged flame barrier core should be cleaned to ensure that each hole in the core is clear and that the fire barrier should be replaced for deformation and corrosion. 
 • When reinstalling the flame retardant core, ensure that the joint surface is tight and leakproof.


RZGB-1 Corrugated Flame Arrester parts material:

Body material Carbon steel WCB, stainless steel 304,316
Fire retardant core material Stainless steel explosion-proof corrugated plate
Sealing material Asbestos rubber, PTFE PTFE
Ambient temperature ℃ ≤480
Nominal pressure (MPa) 0.6 ~ 5.0
Explosion-proof level BS5501: Ⅱ A, Ⅱ B, Ⅱ C


Reminder:

All text, data and pictures in this article are for reference only.To see more details of the RZGB-1 Corrugated Flame Arrester performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.

+86-021-57278881
qrCode