BH41W/H Insulation Check Valve
Product overview
Product model: BH41W/H
Nominal diameter: DN10~2000mm
Nominal pressure: PN1.6~16.0MPa
Main material: stainless steel (316L, 304, CF3M, CF8), double-phase steel, carbon steel, titanium material
Design and manufacturing standards: GB/T12235, GB/T12236, API6D
Structure length standard: GB/T 12221-2005, ASME B16.10
Connecting flange standard: GB/T 9113, GB, HG, JB, API, DIN, JIS
Pressure and temperature grade: GB/T 12224-2005
Test standards: GB/T 13927-2008, JB/T9092, API598
BH41W/H Insulation Check Valve works:
BH41W/H Insulation Check Valve produced and sold by Baigang valve group is lifting the check valve on the basis of welding metal jacket, used to inject steam or other insulation, cold medium, to ensure that the valve medium to work properly. Has a good thermal insulation properties, while reducing the pipeline medium heat loss. Insulation jacket check valve Integral jacket structure design, more uniform insulation, cold, jacketed carbon steel pipe welding more firm than the cast. Jacket, outside the body and jacket take over welding, allowing steam or cold water maximum pressure of 1MPa.
BH41W/H Insulation Check Valve Features:
1, lifting insulation check valve has a good thermal insulation properties, while reducing the pipeline medium heat loss.
2, Widely used Mainly used in petroleum, chemical industry, asphalt, metallurgy, pharmaceutical, food and other systems, to prevent the delivery of conventional high viscosity medium will be solidified reflux.
3, the use of carbon steel jacket welded more firm than the casting pressure.
BH41W/H Insulation Check Valve main form connection size:
GB 1.6MPa | ||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
L | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 650 | 750 |
H | 90 | 95 | 100 | 105 | 110 | 115 | 140 | 170 | 200 | 230 | 255 | 285 | 290 | 300 |
Wt | 14 | 15 | 16 | 17 | 18 | 19 | 24 | 29 | 40 | 58 | 83 | 100 | 105 | 110 |
GB 2.5MPa | ||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
L | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 650 | 750 |
H | 90 | 95 | 100 | 105 | 110 | 115 | 140 | 170 | 200 | 230 | 260 | 285 | 290 | 300 |
Wt | 14 | 15 | 16 | 17 | 18 | 19 | 24 | 29 | 40 | 72 | 104 | 145 | 180 | 230 |
GB 4.0MPa | ||||||||||||||
DN | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |||
L | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 650 | 750 | |||
H | 120 | 140 | 150 | 160 | 175 | 200 | 225 | 260 | 315 | 320 | 300 | |||
Wt | 9 | 12 | 15 | 20 | 33 | 41 | 73 | 104 | 147 | 180 | 230 | |||
GB 6.4MPa | ||||||||||||||
DN | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |||
L | 230 | 260 | 300 | 340 | 380 | 430 | 500 | 550 | 600 | 775 | 900 | |||
H | 160 | 170 | 170 | 190 | 205 | 230 | 265 | 310 | 350 | 480 | 520 | |||
Wt | 12 | 20 | 29 | 35 | 47 | 68 | 100 | 142 | 195 | 250 | 300 |
GB10.0MPa | ||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
L | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 650 | 750 |
H | 90 | 95 | 100 | 105 | 110 | 115 | 140 | 170 | 200 | 230 | 255 | 285 | 290 | 300 |
Wt | 14 | 15 | 16 | 17 | 18 | 19 | 24 | 29 | 40 | 58 | 83 | 100 | 105 | 110 |
GB 16.0MPa | ||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
L | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 650 | 750 |
H | 90 | 95 | 100 | 105 | 110 | 115 | 140 | 170 | 200 | 230 | 260 | 290 | 290 | 300 |
Wt | 14 | 15 | 16 | 17 | 18 | 19 | 24 | 29 | 40 | 72 | 104 | 180 | 180 | 230 |
Reminder:
All text, data and pictures in this article are for reference only.To see more details of the BH41W/H Insulation Check Valve performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.